Triton X-SCALE/X2 Configuration Manual Bedienungsanleitung Seite 29

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 419
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 28
19
TERMINAL CLOSE FUNCTIONS
Note: For NMD-50/100 only, cassettes will
automatically U
NLOCK.
Note: For NMD-50/100 only, cassettes will
automatically LOCK. Press <ENTER>.
For the NMD-50/100 dispensing mechanisms, the
cassettes MUST be LOCKED and IN-SERVICE for
normal operation
.
Place selected cassette(s) IN SERVICE (MULTI-
CASSETTE DISPENSERS ONLY). Press <ENTER> to
continue.
Enter CASSETTE QUANTITY (# of notes, NOT
value) for selected cassette. Press <ENTER> to
accept the entry. Repeat for remaining
cassette(s).
A TRIAL CASSETTE
CLOSE report appears to be
printed or saved. Press
<ENTER> after printing and
retain copy for starting
point reference.
R
EMOVE and REPLENISH selected cassette(s).
After reinserting cassette(s), press <ENTER>.
Seitenansicht 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 418 419

Kommentare zu diesen Handbüchern

Keine Kommentare