June 2004 Isis® Sonar User's Manual, Volume 2 128
Figure I-1. Opening advisory screen about EdgeTech DF-1000 sonars
3. Observe the jumper settings that must be established for Isis to work correctly
with these sonars.
N
otice to Isis users with DF1000 DCU di
g
ital inter
f
ace:
S
tartin
g
with Isis version 4.14 the method o
f
inter
f
acin
g
to this sonar chan
g
ed.
Version 4.14 requires some different links to be made in the EdgeTech DF1000
D
CU deck unit. The messa
g
e that appears in Isis versions 4.14 throu
g
h 4.31
g
ives incorrect information on the details of these changes. The correct
information is:
Open the Edgetech deck unit and verify the following jumper
settings: JP15=CONT, JP17=IRQ+, JP16=DRQ+
.”