SUPPLEMENT D
SD-3
FULLY SUPPORTS TDM-2XX RETURN CODES
This release fully supports the TDM-2XX return codes. There are two classes of return codes where one
is a soft error that the terminal will accept and retry the failed command. The second class is a fatal error
and will cause the terminal to not retry and go out of service with the error code.
TEST DISPENSE WITH TDM-2XX RETURN CODE INTACT
The TDM-2XX reports a status of the test dispense operation. This release corrects the reporting of that
status information.
TEST FOR TDM-1XXS BEFORE TDM-2XXS
This release corrects the problem of newer TDM firmware that responds to both command sets of the
TDM product line. These command sets changes the way that cassettes are managed and error codes
that are reported. This release will test for a single cassette TDM before testing for a TDM multi-cassette
mechanism.
CORRECTING THE SCREEN FLOW FOR THE PRINTER OFF-LINE NOTIFICATION
The Printer off-line notification will now return the customer to the Transaction Cancelled screen then to
the Welcome Screen when the No is selected or the screen exhausts its timeout waiting for input from the
customer.
AUTO RECOVERY FROM 139 PRINTER ERROR (9100 ONLY)
This maintenance release adds the capability to the terminal to auto-recover from an 139 error if possible.
The 139 error condition indicates that the terminal experienced a problem with the printer. Previous
releases required the Terminal Owner to restart the terminal and then reset the error. Now if the printer
recovers from the error, the terminal will constantly test for this state and automatically reset the error and
return into service. If paper was out when this error occurred, within 30 seconds of paper being reloaded,
the terminal will go back in service.
DEFAULT PASSWORD DETECTION
The terminal will no longer go into service if the Master and/or Administration passwords are configured
in their default setting. A new error code (246) will be displayed when the passwords are in their default
state. The terminal will detect this condition and go out of service. On the “Out of Service” screen,
no error information will be displayed. The following are screen captures of this state. This error
code will not clear until the Master and/or the Administration passwords are changed from their